  "name": "HVAC Calculator",
  "id": "hvac-calculator",
  "publisher": "FieldRanger",
  "description": "Estimates cooling capacity in BTU per hour and tons by a named rule of thumb (ENERGY STAR's room air conditioner chart, or BTU per square foot). It is not a Manual J load calculation.",
  "page": "https://fieldranger.ai/templates/hvac-calculator",
  "endpoint": "https://fieldranger.ai/api/tools/hvac-calculator",
  "usage": "GET with query parameters, or POST a JSON object with the same names, returns the computed result. GET with no parameters returns this description.",
  "inputs": [
    {
      "name": "method",
      "label": "Method",
      "type": "string (enum)",
      "required": false,
      "default": "energy-star-room",
      "enum": [
        {
          "value": "energy-star-room",
          "label": "ENERGY STAR room chart"
        },
        {
          "value": "btu-per-sqft",
          "label": "BTU per square foot"
        }
      ],
      "description": "ENERGY STAR's room chart, or area times a factor the user enters."
    },
    {
      "name": "area",
      "label": "Area to cool",
      "type": "number",
      "unit": "sq ft",
      "required": false,
      "default": 400,
      "defaultIsSample": true,
      "minimum": 1,
      "maximum": 100000,
      "description": "Floor area of the space."
    },
    {
      "name": "exposure",
      "label": "Sun exposure",
      "type": "string (enum)",
      "required": false,
      "default": "normal",
      "enum": [
        {
          "value": "normal",
          "label": "Normal"
        },
        {
          "value": "shaded",
          "label": "Heavily shaded"
        },
        {
          "value": "sunny",
          "label": "Very sunny"
        }
      ],
      "onlyWhen": "method is energy-star-room",
      "description": "ENERGY STAR adjusts 10% down for heavy shade and 10% up for a very sunny room."
    },
    {
      "name": "occupants",
      "label": "Regular occupants",
      "type": "integer",
      "unit": "people",
      "required": false,
      "default": 2,
      "minimum": 0,
      "maximum": 50,
      "onlyWhen": "method is energy-star-room",
      "description": "600 BTU/h is added for each person above two."
    },
    {
      "name": "kitchen",
      "label": "Kitchen",
      "type": "boolean",
      "required": false,
      "default": false,
      "onlyWhen": "method is energy-star-room",
      "description": "Adds 4,000 BTU/h."
    },
    {
      "name": "btuPerSqFt",
      "label": "BTU per square foot",
      "type": "number",
      "unit": "BTU/h per sq ft",
      "required": false,
      "default": 20,
      "defaultIsSample": true,
      "minimum": 1,
      "maximum": 100,
      "onlyWhen": "method is btu-per-sqft",
      "description": "The user's own rule-of-thumb factor."
    }
  ],
  "outputs": [
    {
      "name": "btuPerHour",
      "label": "Cooling capacity",
      "unit": "BTU/h",
      "type": "number",
      "description": "Base capacity plus adjustments."
    },
    {
      "name": "tons",
      "label": "Tons",
      "unit": "tons",
      "type": "number",
      "description": "BTU/h / 12,000."
    },
    {
      "name": "baseBtuPerHour",
      "label": "Base capacity",
      "unit": "BTU/h",
      "type": "number",
      "description": "Chart value, or area x factor."
    },
    {
      "name": "adjustments",
      "label": "Adjustments",
      "type": "array",
      "description": "Each adjustment applied, with its BTU/h."
    },
    {
      "name": "methodName",
      "label": "Method",
      "type": "string",
      "description": "The rule of thumb used."
    }
  ],
  "example": {
    "request": "https://fieldranger.ai/api/tools/hvac-calculator?method=energy-star-room&area=400&exposure=sunny&occupants=3&kitchen=false",
    "post": {
      "url": "https://fieldranger.ai/api/tools/hvac-calculator",
      "body": {
        "method": "energy-star-room",
        "area": 400,
        "exposure": "sunny",
        "occupants": 3,
        "kitchen": false
      }
    },
    "response": {
      "tool": "hvac-calculator",
      "title": "HVAC Calculator",
      "inputs": {
        "method": "energy-star-room",
        "area": 400,
        "exposure": "sunny",
        "occupants": 3,
        "kitchen": false
      },
      "result": {
        "method": "energy-star-room",
        "methodName": "ENERGY STAR room air conditioner sizing chart",
        "baseBtuPerHour": 10000,
        "adjustments": [
          {
            "label": "Very sunny: +10%",
            "btuPerHour": 1000
          },
          {
            "label": "1 occupant above two: +600 each",
            "btuPerHour": 600
          }
        ],
        "btuPerHour": 11600,
        "tons": 0.97
      },
      "summary": [
        {
          "label": "Cooling capacity",
          "value": "11,600 BTU/h",
          "primary": true
        },
        {
          "label": "Tons",
          "value": "0.97",
          "primary": true
        },
        {
          "label": "Method",
          "value": "ENERGY STAR room air conditioner sizing chart"
        },
        {
          "label": "Base capacity",
          "value": "10,000 BTU/h"
        },
        {
          "label": "Very sunny: +10%",
          "value": "+1,000 BTU/h"
        },
        {
          "label": "1 occupant above two: +600 each",
          "value": "+600 BTU/h"
        }
      ],
      "notes": [
        "Rule of thumb, not a Manual J load calculation: confirm equipment size with a load calculation before quoting it."
      ],
      "text": "HVAC Calculator (FieldRanger, https://fieldranger.ai)\n\nInputs\n- Method: ENERGY STAR room chart\n- Area to cool: 400 sq ft (sample)\n- Sun exposure: Very sunny\n- Regular occupants: 3 people\n- Kitchen: no\n\nResult\n- Cooling capacity: 11,600 BTU/h\n- Tons: 0.97\n- Method: ENERGY STAR room air conditioner sizing chart\n- Base capacity: 10,000 BTU/h\n- Very sunny: +10%: +1,000 BTU/h\n- 1 occupant above two: +600 each: +600 BTU/h\n\nNotes\n- Rule of thumb, not a Manual J load calculation: confirm equipment size with a load calculation before quoting it.\n\nMethod: ENERGY STAR method: look up the capacity for the area in ENERGY STAR's room air conditioner chart (100 to 2,500 sq ft, 8-foot ceiling). Adjust: heavily shaded -10%, very sunny +10%, +600 BTU/h for each regular occupant above two, +4,000 BTU/h for a kitchen. Rule-of-thumb method: BTU/h = area x the BTU-per-square-foot factor entered. Tons = BTU/h / 12,000 (one ton of air conditioning is 12,000 BTU/h).\nCalculator: https://fieldranger.ai/templates/hvac-calculator",
      "method": [
        "ENERGY STAR method: look up the capacity for the area in ENERGY STAR's room air conditioner chart (100 to 2,500 sq ft, 8-foot ceiling).",
        "Adjust: heavily shaded -10%, very sunny +10%, +600 BTU/h for each regular occupant above two, +4,000 BTU/h for a kitchen.",
        "Rule-of-thumb method: BTU/h = area x the BTU-per-square-foot factor entered.",
        "Tons = BTU/h / 12,000 (one ton of air conditioning is 12,000 BTU/h)."
      ],
      "sources": [
        {
          "label": "ENERGY STAR: Room Air Conditioners, sizing chart and adjustments",
          "url": "https://www.energystar.gov/products/room_air_conditioners",
          "checked": "2026-11-13"
        },
        {
          "label": "Allison Bailes, Energy Vanguard: Why Is Air Conditioner Capacity Measured in Tons?",
          "url": "https://www.energyvanguard.com/blog/Why-Is-Air-Conditioner-Capacity-Measured-in-Tons",
          "published": "2012-09-21",
          "checked": "2026-11-13"
        },
        {
          "label": "ACCA, Manual J: Residential Load Calculation",
          "url": "https://www.acca.org/standards/technical-manuals/manual-j",
          "checked": "2026-11-13"
        }
      ],
      "caveats": [
        "A rule of thumb, not a load calculation. Equipment for a house is sized from an ACCA Manual J load calculation and selected with Manual S; square-foot rules ignore insulation, windows, orientation, infiltration and climate.",
        "ENERGY STAR's chart sizes a room air conditioner for one room with an 8-foot ceiling.",
        "The BTU-per-square-foot factor is the user's own assumption; no single factor holds across climates and houses."
      ],
      "page": "https://fieldranger.ai/templates/hvac-calculator",
      "endpoint": "https://fieldranger.ai/api/tools/hvac-calculator",
      "publisher": "FieldRanger",
      "disclosure": "Published by FieldRanger (https://fieldranger.ai), field service software that runs inside HubSpot. The calculation is free and needs no sign-up or email. FieldRanger does not calculate loads or size equipment. Related FieldRanger features: A won HubSpot deal becomes a job with its context carried over. Create templates for maintenance contracts and repeat service calls. FieldRanger plans: https://fieldranger.ai/pricing."
    }
  },
  "method": [
    "ENERGY STAR method: look up the capacity for the area in ENERGY STAR's room air conditioner chart (100 to 2,500 sq ft, 8-foot ceiling).",
    "Adjust: heavily shaded -10%, very sunny +10%, +600 BTU/h for each regular occupant above two, +4,000 BTU/h for a kitchen.",
    "Rule-of-thumb method: BTU/h = area x the BTU-per-square-foot factor entered.",
    "Tons = BTU/h / 12,000 (one ton of air conditioning is 12,000 BTU/h)."
  ],
  "sources": [
    {
      "label": "ENERGY STAR: Room Air Conditioners, sizing chart and adjustments",
      "url": "https://www.energystar.gov/products/room_air_conditioners",
      "checked": "2026-11-13"
    },
    {
      "label": "Allison Bailes, Energy Vanguard: Why Is Air Conditioner Capacity Measured in Tons?",
      "url": "https://www.energyvanguard.com/blog/Why-Is-Air-Conditioner-Capacity-Measured-in-Tons",
      "published": "2012-09-21",
      "checked": "2026-11-13"
    },
    {
      "label": "ACCA, Manual J: Residential Load Calculation",
      "url": "https://www.acca.org/standards/technical-manuals/manual-j",
      "checked": "2026-11-13"
    }
  ],
  "caveats": [
    "A rule of thumb, not a load calculation. Equipment for a house is sized from an ACCA Manual J load calculation and selected with Manual S; square-foot rules ignore insulation, windows, orientation, infiltration and climate.",
    "ENERGY STAR's chart sizes a room air conditioner for one room with an 8-foot ceiling.",
    "The BTU-per-square-foot factor is the user's own assumption; no single factor holds across climates and houses."
  ],
  "inputSchema": {
    "$schema": "https://json-schema.org/draft/2020-12/schema",
    "$id": "https://fieldranger.ai/api/tools/hvac-calculator#input",
    "title": "HVAC Calculator: input",
    "description": "Estimates cooling capacity in BTU per hour and tons by a named rule of thumb (ENERGY STAR's room air conditioner chart, or BTU per square foot). It is not a Manual J load calculation.",
    "type": "object",
    "properties": {
      "method": {
        "title": "Method",
        "description": "ENERGY STAR's room chart, or area times a factor the user enters.",
        "type": "string",
        "enum": [
          "energy-star-room",
          "btu-per-sqft"
        ],
        "default": "energy-star-room"
      },
      "area": {
        "title": "Area to cool",
        "description": "Floor area of the space. Unit: sq ft. The default is a sample value; replace it with the caller's own.",
        "type": "number",
        "minimum": 1,
        "maximum": 100000,
        "default": 400,
        "x-unit": "sq ft",
        "x-sample": true
      },
      "exposure": {
        "title": "Sun exposure",
        "description": "ENERGY STAR adjusts 10% down for heavy shade and 10% up for a very sunny room. Only read when method is energy-star-room.",
        "type": "string",
        "enum": [
          "normal",
          "shaded",
          "sunny"
        ],
        "default": "normal"
      },
      "occupants": {
        "title": "Regular occupants",
        "description": "600 BTU/h is added for each person above two. Unit: people. Only read when method is energy-star-room.",
        "type": "integer",
        "minimum": 0,
        "maximum": 50,
        "default": 2,
        "x-unit": "people"
      },
      "kitchen": {
        "title": "Kitchen",
        "description": "Adds 4,000 BTU/h. Only read when method is energy-star-room.",
        "type": "boolean",
        "default": false
      },
      "btuPerSqFt": {
        "title": "BTU per square foot",
        "description": "The user's own rule-of-thumb factor. Unit: BTU/h per sq ft. Only read when method is btu-per-sqft. The default is a sample value; replace it with the caller's own.",
        "type": "number",
        "minimum": 1,
        "maximum": 100,
        "default": 20,
        "x-unit": "BTU/h per sq ft",
        "x-sample": true
      }
    },
    "required": [],
    "additionalProperties": false
  },
  "disclosure": "Published by FieldRanger (https://fieldranger.ai), field service software that runs inside HubSpot. The calculation is free and needs no sign-up or email. FieldRanger does not calculate loads or size equipment. Related FieldRanger features: A won HubSpot deal becomes a job with its context carried over. Create templates for maintenance contracts and repeat service calls. FieldRanger plans: https://fieldranger.ai/pricing."
}