An air duct cleaning business cleans the supply and return ducts, registers and, where licensed, the air handler of heating and cooling systems in homes and commercial buildings. Starting one takes a check of which work the state licenses, liability insurance, a collection and agitation equipment package, NADCA certification for membership, and a price set per system.

The decisions that sink a new duct cleaning company are made before the first job. A truck is equipped to clean coils and blowers in a state where that work needs an HVAC contractor license the owner does not hold. A commercial bid is lost because the specification names an ASCS-certified technician and nobody on staff has passed the exam. Insurance is bought at a limit below the one a license or a property manager demands. FieldRanger makes the cleaning app for service businesses on HubSpot, and this guide covers the duct cleaning business from licensing to its first full year. It starts with Texas's rule on what an unlicensed duct cleaner may touch, then residential and commercial work, NADCA's standard, certification and membership fees, equipment packages and insurance. A costed first year in Corpus Christi, Texas, a start-up checklist and the software record follow.

Four terms recur. The air distribution system is the ductwork between the air handler and the rooms: supply ducts, return ducts, registers and grilles. The air handler is the cabinet holding the blower and, where the system has one, the cooling coil. A system is one air handler with the ducts it serves, which is the unit a duct cleaning price is quoted in. Agitation is the brushing, air whipping or skipping that loosens debris so the collection unit can pull it out under negative pressure.

Texas licensing scope for duct cleaning

Texas draws its line in the ductwork itself. The Texas Department of Licensing and Regulation's rule states that duct cleaning and air quality testing "may be performed by a person or entity that does not hold a contractor license" under Occupations Code Chapter 1302, if four conditions hold:

  1. The task is limited to the air distribution system, "from the supply plenum to the supply grilles" and "from the return air grill to the air handler intake".
  2. No cuts are made to ducts or plenums.
  3. No changes are made to electrical connections.
  4. The only disassembly is opening or removing grilles and registers that come off without cutting or removing any other part of the system.

The text is 16 Texas Administrative Code §75.100(c) (Cornell LII, 16 Tex. Admin. Code §75.100, read November 13, 2026). TDLR's May 2026 proposal to amend Chapter 75 lists changes to technician designations, exam eligibility, Texas Education Agency references and the adopted code editions, and does not list the duct cleaning provision (TDLR, summary of proposed rule changes, May 12, 2026).

The rule decides the business model. Cleaning the blower and coil happens inside the air handler, past the intake. Cutting an access hole is a cut to a duct. Both fall outside the unlicensed scope, and TDLR states that non-exempt air conditioning and refrigeration work "must be provided through a Texas licensed Air Conditioning and Refrigeration Contractor who holds the required amount of liability insurance" (TDLR, air conditioning and refrigeration FAQ, read November 13, 2026). A new Texas company therefore chooses one of three models:

  • Ducts only. Work stays inside §75.100(c): ducts cleaned through register openings, with no access holes and no air handler work.
  • Licensed company. The owner, or an employee, holds the contractor license, and the company does the full system.
  • Paired with a licensed contractor. The duct cleaner does the ducts and a licensed contractor does the air handler and any cut, under a written arrangement.

The license is not quick to obtain. TDLR requires 48 months of supervised practical experience in the past 72 months, or 36 months plus a technician certification held for 12 months, a $115 application fee and a passed exam. Class B covers cooling systems of 25 tons and under (TDLR, apply for a contractor license, read November 13, 2026). An owner new to the trade starts in the first or third model. Other states draw the line elsewhere: NADCA's membership page lists Arizona, Arkansas, California, Florida, Georgia, Michigan and Texas among states that require an HVAC, mechanical, sheet metal or other specialty license "to access and clean HVAC systems" (NADCA, new member package for regular members, read November 13, 2026).

Residential and commercial duct cleaning work

The two markets buy the same service under different terms.

Residential and commercial duct cleaning compared
ElementResidentialCommercial
BuyerHomeowner, landlord, home sellerFacility manager, general contractor, building owner
How work is wonPhone call or web form, price per systemBid against a written specification
Scope referenceThe company's own scope, or ACR on requestACR, the NADCA standard, named in the specification
Staffing conditionNone set by the buyerSpecifications that name an ASCS-certified technician on the project
ScheduleDaytime, one system in a visitNights and weekends, many air handlers over several visits
PaperworkEstimate, photos, invoiceBid, certificate of insurance, before and after records, verification report

NADCA's certification page states that "many job specifications require that a certified ASCS be on a project" (NADCA, Air Systems Cleaning Specialist, read November 13, 2026). Commercial work under such a specification is closed to a company without the certificate, whatever its equipment. Residential work is open from the first day, priced per system with stated counts of registers and returns. The fields of that estimate are on the cleaning estimate template. The ways a per-vent price goes wrong are set out in air duct cleaning estimate problems.

NADCA standard, ASCS certification and membership fees

The industry's reference is ACR, the NADCA Standard for the Assessment, Cleaning, and Restoration of HVAC Systems, in its 2025 edition. NADCA offers it as a free download. It covers assessing HVAC systems, cleaning them to a specified level and verifying the cleanliness of system components (NADCA, ACR 2025 Edition, read November 13, 2026). In Texas, those components include parts past the plenum that the unlicensed scope does not reach.

The Air Systems Cleaning Specialist (ASCS) credential is NADCA's exam-based certificate. NADCA sets no formal eligibility prerequisites and recommends two to four years of field experience before the exam. The exam is $385, a retake is $100, and it is taken at a testing center or a NADCA event (NADCA, how to get ASCS certified, read November 13, 2026). Certification renews by June 30 each year, with six continuing education credits and an annual maintenance fee of $95 for members and $920 for non-members (NADCA, how to renew ASCS, read November 13, 2026).

Regular membership requires three things: annual dues, an ASCS-certified individual on staff at each location, and a certificate of liability insurance naming NADCA as certificate holder. A pending applicant has six months to meet them and may not use the NADCA logo until approved. The new-member package table lists dues at $995, a $100 application fee, ASCS online training at $290 against a regular $395, VMT online training at $50 against $175, and the $385 exam, with a total of $1,850. The listed items sum to $1,820, and the FAQ on the same page gives dues of $935.00 a year (NADCA new member package page, read November 13, 2026). An applicant confirms the amount due with NADCA before budgeting.

The non-member renewal fee shapes the decision. An ASCS holder at a non-member company pays $920 a year to renew, against $95 at a member company, so the certificate and the membership are bought together.

Duct cleaning equipment packages and prices

A duct cleaning rig has four parts: a collection unit that holds the system under negative pressure, a compressor that drives air tools, agitation tools that loosen debris, and the hose, plugs and hole cutters that connect them. Nikro, a maker of portable units, sells all four as packages. Jendco Safety Supply, a distributor, listed two on November 13, 2026.

Two Nikro duct cleaning packages listed by Jendco Safety Supply (checked November 13, 2026)
PackageCollection unitCompressor and toolsListed price
[Nikro #4 Gasoline Powered](https://www.jendcosafety.com/nikro-4-gasoline-powered-air-duct-cleaning-package)HP20GAS, 20 HP Kohler engine, 5,100 CFM free air, 16 inches static pressure, 370 lb9 HP gasoline compressor, 19.2 CFM delivered at 175 PSI; three 50-foot airlines; an air tool; a 20-foot brush system with nylon and silicon carbide brushes; 1-inch cap plugs$9,962.95, against $11,237.99 list
[Nikro #3 Deluxe](https://jendcosafety.com/nikro-3-deluxe-air-duct-cleaning-package)PDC4000 electric, 5,000 CFM free air, 5 inches static pressure, 3-stage HEPA filtration, 115 V on two plugs, 210 lbThe same compressor, a whip and blast system, brushes, a 10-gallon HEPA vacuum, hole cutters, 1-inch and 2½-inch plugs, a ULV fogger and a pail of duct sanitizer$10,099.95, against $11,653.99 list

The two packages split on power and filtration. The gasoline unit brings its own engine and stands outside with its hoses run in, so it needs no house circuits. The electric unit draws on two 115-volt plugs and filters through HEPA, so it can run indoors. The #3 package's hole cutters and plugs are tools for a cut that, in Texas, belongs to a licensed contractor, and its fogger and sanitizer serve a chemical treatment that the air duct cleaning estimate problems guide prices as its own line. A ducts-only company in Texas buys the collection unit, compressor and agitation tools and leaves the rest.

A truck-mounted unit is the larger alternative, with its own engine on the vehicle and a vehicle dedicated to it. It suits a company whose bookings already fill a portable unit's week.

Insurance minimums and median premiums

Three parties can set the insurance a duct cleaner carries: the state license, the trade association and the customer. In Texas, a Class B contractor license requires commercial general liability of $100,000 per occurrence, $200,000 aggregate and $100,000 aggregate for products and completed operations. Class A requires $300,000, $600,000 and $300,000 (TDLR contractor application page, read November 13, 2026). NADCA membership requires a certificate of liability insurance naming NADCA. A commercial specification names its own limits and its own certificate holder.

The license minimums are floors, not market limits. Insureon, an online agency, publishes medians for HVAC installation businesses that buy through it: general liability at $101 a month ($1,213 a year) on a $1 million per occurrence and $2 million aggregate policy with a $500 deductible. Its other medians are workers' compensation at $182 a month ($2,189), commercial auto at $286 ($3,438), tools and equipment at $41 ($495) and a surety bond at $9 (Insureon, HVAC business insurance cost, updated August 24, 2026). Duct cleaning is not HVAC installation, so these are reference figures for an application, not quotes. The coverage each policy answers, and the certificates a property manager asks for, are set out in cleaning business insurance.

Sample first year: one truck in Corpus Christi, Texas

The business is hypothetical: the owner holds the ASCS certificate and works as lead technician, with one paid helper and the Nikro #4 package. It works inside the Texas ducts-only scope on residential jobs. It also sells six commercial jobs a year, on which a licensed contractor partner cleans the air handlers and bills that work to the customer directly, under a written arrangement (sample). Job counts, prices, hours, mileage, fuel use, the van lease and the overhead lines are sample inputs, labelled as such.

Four rates are sourced. The helper is paid $17.74 an hour, the 75th percentile for janitors and cleaners in the Corpus Christi metro in BLS 2025 wage data; the HVAC mechanic median there is $24.89 (O\*NET OnLine, Texas wages for 37-2011.00 and 49-9021.00, read November 13, 2026). The employer adds 7.65 percent for Social Security and Medicare (IRS, Topic no. 751, read November 13, 2026). Fuel is the Texas average for regular gasoline, $3.408 a gallon in the week of November 9, 2026 (EIA, Gasoline and Diesel Fuel Update, released November 10, 2026). Insurance is the Insureon median set above.

Sample first year for a one-truck air duct cleaning business in Corpus Christi (sourced rates; sample volumes and prices)
LineCalculationAmount
Residential systems250 × $525.00, sample price per system$131,250.00
Dryer vents sold on the same visit90 × $120.00, sample; the trade's own rules are in [dryer vent cleaning business](/blog/dryer-vent-cleaning-business)$10,800.00
Commercial jobs to ACR6 × $3,200.00, sample$19,200.00
RevenueSum$161,250.00
Helper wages2,000 paid hours × $17.74$35,480.00
Social Security and Medicare7.65% of wages$2,714.22
Equipment$9,962.95 ÷ 5 years, plus a camera ($600 ÷ 3) and HEPA vacuum ($800 ÷ 3), samples$2,459.26
Van lease (sample)$650 a month$7,800.00
Van fuel6,240 miles ÷ 14 miles a gallon (sample) × $3.408$1,518.99
Collection unit and compressor fuel846 engine hours (sample) × 1.8 gallons an hour (sample) × $3.408$5,189.70
InsuranceGeneral liability $1,213, commercial auto $3,438, tools $495, workers' compensation $2,189$7,335.00
NADCA, first yearNew-member package total as listed$1,850.00
Marketing, phone and software, supplies, accounting (samples)$6,000 + $1,800 + $1,500 + $1,200$10,500.00
Total costSum$74,847.17
Result before the owner's pay and income taxes$161,250.00 − $74,847.17$86,402.83

The result pays the owner, who works every job, and carries self-employment and income tax. Two lines move it most. The first is the price per system: at $475 instead of $525, revenue falls by $12,500. The second is the licensing model. If 100 of the 250 homes want the blower and coil cleaned, and the company buys that work from a licensed contractor at a sample $110 a system, the year carries $11,000 more cost, or forfeits the work to whoever holds the license. Equipment, at $2,459.26, is the smallest decision in the table.

Air duct cleaning business start-up checklist

  1. Read the state's rule on duct cleaning and the HVAC license before buying equipment; in Texas, §75.100(c) and the TDLR contractor requirements.
  2. Choose the model: ducts only, licensed company, or paired with a licensed contractor, and put any pairing in writing.
  3. Register the business and obtain any city or county license.
  4. Buy general liability at or above the limits the license, NADCA and the first commercial specification require, plus commercial auto and workers' compensation before the first hire.
  5. Pass the ASCS exam and apply for NADCA membership in the same season, so the renewal is charged at the member rate.
  6. Buy the collection unit, compressor and agitation tools that fit the chosen scope, and leave out tools for work the company may not do.
  7. Write the residential price per system, with the register and return counts it assumes.
  8. Prepare a commercial bid file: ASCS certificate, certificate of insurance and a sample ACR verification record.
  9. Verify the setup on the first paid job: the work done matches the licensed scope, the photos show each register before and after, and the hours logged match the hours in the price.

Duct cleaning jobs, estimates and invoices in FieldRanger

FieldRanger runs the job side of a duct cleaning company inside HubSpot. Estimates built in HubSpot are built from the deal or contact record without leaving HubSpot, Estimates built in FieldRanger stay tied to the HubSpot deal, and PandaDoc sends estimates and agreements for signature. Won deals become jobs carries the deal's context into the job. Each job is assigned to a technician on the Drag-and-drop calendar, and Auto-routing builds each technician's route for the day.

On site, Photo documentation attaches before and after photos to the work order, Custom checklists can hold the scope limits a Texas ducts-only job must keep to, and Job-level time tracking logs the hours against each job. Invoices from completed work orders produce the bill, Stripe takes payment in the field, QuickBooks syncs invoices and payments, and Revenue reports show job revenue and margin by service type, so the residential and commercial lines in the sample can be checked against actual results. Recurring job templates hold repeat commercial cleanings.

With Online booking, homeowners book a visit online. Multi-day jobs are not built: a commercial project cleaned over three nights is three jobs, one for each night. Plans, and Start free trial for 14 days with no card, are on pricing.

Frequently asked questions

How to start an air duct cleaning business?

Read the state's rule on which duct and HVAC work needs a contractor license, register the business, buy liability insurance at the limits the license and customers require, pass NADCA's ASCS exam, buy a collection unit, compressor and agitation tools for the permitted scope, and price residential work per system.

Is a license required for air duct cleaning in Texas?

Not for duct cleaning limited to the air distribution system with no cuts, no electrical changes and no disassembly beyond grilles and registers, under 16 TAC §75.100(c). Work inside the air handler or cutting access holes goes through a TDLR-licensed air conditioning and refrigeration contractor.

How much does NADCA ASCS certification cost?

The ASCS exam is $385 and a retake $100. Renewal each June needs six continuing education credits and an annual fee of $95 for NADCA members or $920 for non-members, as listed on nadca.com in November 2026.

How much is air duct cleaning equipment?

Jendco Safety Supply listed Nikro's gasoline-powered package #4 at $9,962.95 and its electric HEPA package #3 at $10,099.95 on November 13, 2026, each with a collection unit, compressor and agitation tools. A ducts-only company in Texas leaves out the hole cutters and plugs.

What insurance does an air duct cleaning business need?

General liability, commercial auto, and workers' compensation once it hires. A Texas Class B contractor license requires at least $100,000 per occurrence, and NADCA membership requires a certificate of liability insurance naming NADCA. Insureon's median for HVAC installers is $101 a month for a $1 million policy.

What is the difference between residential and commercial duct cleaning?

Residential work is sold per system after a phone or web inquiry. Commercial work is bid against a written specification that names ACR, the NADCA standard, and in many cases an ASCS-certified technician on the project, with night or weekend work and a verification record.

Equipment costs the Corpus Christi company $2,459.26 a year and the licensing model moves its result by $11,000, so the state's duct cleaning rule is read before the rig is bought.

Run field service on HubSpot with FieldRanger

Estimates with e-signature, scheduling and dispatch, a technician mobile app and invoicing, synced to the HubSpot deals and contacts the business already keeps.

Book a demo