Template

Construction Roofing Siding and Windows Checklist:Underlayment, Ice Dam, Shingle and Valley Items, Wall Flashing, Water-Resistive Barrier, Window Flashing Steps and a Filled Appleton, Wisconsin House

Construction roofing siding and windows checklist: Wisconsin code roof and wall flashing items, Marvin window flashing steps and a filled Appleton house.

Updated 13 min read

Download .xlsxExcel spreadsheet · 18 KB · Free, no sign-upFill it in online

A construction roofing siding and windows checklist is the exterior contractor's record that the building envelope sheds water before each layer is covered: roof underlayment, ice dam protection, shingle fastening and valley flashing, the water-resistive barrier, window flashing, wall flashing and siding penetrations. The filled example inspects a new two-story house in Appleton, Wisconsin.

FieldRanger, the roofing contractor software that runs inside HubSpot, keeps this checklist among its free field service templates. The page offers the tables as a free .xlsx download with no sign-up: a Template sheet with every check and a result column, and a Sample sheet with the filled inspection. Roof and wall rows cite Wisconsin's Uniform Dwelling Code, chapter SPS 321 (Register November 2024 No. 827). Window rows follow Marvin's published flashing instruction, document 19913776, dated April 29, 2026.

Envelope checks in the order work is covered

The checklist runs in the order the work disappears. A water-resistive barrier lap cannot be inspected once siding covers it, and a window's sill pan cannot be seen once the window sits on it. Each row is therefore checked at its own hold point, before the next trade covers it, and the form records the time and the inspector for each group.

Wisconsin writes one hold point into the code. Under SPS 321.24(2), "wall cavity insulation may not be installed until a water-resistant covering is in place over the wall cavity and windows, doors and a roof with at least underlayment are installed" (Wisconsin Administrative Code, chapter SPS 321, Register November 2024 No. 827, read November 13, 2026). The envelope checklist is the evidence the insulation crew may start.

This checklist covers water, not people. The job site safety checklist covers fall protection, ladders and the other OSHA construction items for the crew doing the same work.

Roof items under SPS 321.28

Roofing rows, the SPS 321.28 rule behind each, and what the inspector records
ItemRuleWhat the inspector records
Drainage and fasteners321.28(1): roofs "designed and constructed to assure drainage of water"; all fasteners corrosion resistantFastener type from the box label
Underlayment321.28(2): number 15 asphalt-impregnated felt or equivalent, or Type I material showing no water transmission under ASTM D 226 or D 4869; D 1970 materials meet the section by noteProduct name and the standard on its label
Ice dam protection, where required321.28(4)(a): shingled or shake roofs over a heated area of a dwelling or attached garage, with a slope of 4:12 or less; sheet metal or a product labeled ASTM D 1970Slope of each roof plane, and whether the rule applies
Ice dam protection, extent321.28(4)(b): at least 30 inches up the slope from the roof edge and at least 12 inches up the slope beyond the inner face of the exterior wallRequired width computed for each plane; width installed
Shingle label and instructions321.28(3)(a)2 and 3: package labeled to the applicable ASTM standard; shingles installed to the manufacturer's recommendationsShingle product and the instruction sheet on site
Fasteners per shingle321.28(3)(a)4: at least 4 per strip shingle or 2 per interlocking shingle, unless the manufacturer has other specificationsNail count at three lifted shingles per plane
Head lap321.28(3)(a)5: at least 2 inches unless the manufacturer specifies otherwiseMeasured head lap
Flashing locations321.28(7)(a): at chimneys, in all valleys and around all roof openingsEach opening and valley, flashed or not
Open valleys321.28(7)(b): No. 28 gauge corrosion-resistant metal or 50-pound roll roofing, 16 inches wide, over No. 15 underlayment; sections lapped at least 4 inchesValley material, width and laps
Closed valleys321.28(7)(c): 50-pound roofing at least 20 inches wide over No. 15 underlayment, or a product labeled ASTM D1970Valley lining product
Chimney321.28(7)(d): flashed and counter-flashed at least 6 inches high; cricket where the upper side is more than 30 inches wideFlashing height; chimney width and cricket
Reroofing321.28(6): no new covering over wet or deteriorated roofing, over shake, slate, clay or cement tile, or over two or more existing layersLayers found at tear-off, on alterations

The ice dam rule reaches only low-slope planes, and the slope column decides it. A 7:12 main roof falls outside 321.28(4)(a), while a 4:12 roof over a heated room falls inside it. The extent is two tests, and on a deep eave the 12-inch test governs. Its width is the overhang plus the wall thickness, converted to a length along the slope, plus 12 inches. A note under SPS 321.28(3) adds that SPS 320.04(2) applies these roofing provisions to an alteration of any dwelling the code regulates. The same rows therefore serve a reroof on a UDC house.

Wall flashing and water-resistive barrier items under SPS 321.24

Wall rows, the SPS 321.24 rule behind each, and what the inspector records
ItemRuleWhat the inspector records
Barrier coverage321.24(4)(a)1: a water-resistive barrier on wood or metal frame walls "from the highest point to the bottom of the permanent weather-resistant covering"Barrier product; coverage at gables and the bottom edge
Barrier performance321.24(4)(c)1: polymer house wraps rated 5 perms or higher under ASTM E96, with a water-resistance rating under ASTM D779, AATCC 127 or CCMC 07102Product data sheet on site
Barrier laps321.24(4)(d): horizontal seams lapped at least 2 inches, upper over lower; vertical seams at least 6 inches; tears patched the same wayShortest lap found on each wall
Small penetrations321.24(4)(e)2: 5 square inches or less, within the rule's annular-space limit, sealed with caulk or similarEach penetration and its seal
Large penetrations321.24(4)(e)3: over 5 square inches, flashed under subsection (3)Each penetration and its flashing
Flashing joints321.24(3)(c): vertical joints lapped at least 6 inches and sealed; horizontal joints at least 2 inches and sealed unless the flashing manufacturer specifies otherwise; exterior-grade compatible sealantLaps at each flashing joint
Window and door heads321.24(3)(d)1: flashing at the top of all exterior door and window openings, unless self-flashing windows provide at least one inch of flashing around the opening, corners includedHead flashing at each opening
Projecting trim321.24(3)(d)4: flashing continuously above all projecting wood trimEach band board and trim head
Porches, decks and stairs321.24(3)(d)5: where they attach to a wood-frame wall or floorLedger flashing
Wall and roof intersections321.24(3)(d)6 and (e): flashing at intersections; rake-wall flashing extends at least one-half inch down the roof past the head-wall flashingStep and head-wall flashing at each dormer
Roof eave against a sidewall321.24(3)(f): the end of the roof flashing installed so that it "diverts water away from the sidewall and onto the roof or into the gutter"Diverter, or kick-out, at each eave-sidewall corner
Elevated door openings321.24(3)(d)8: flashing along the bottom of door openings above gradeSill flashing at each elevated door

Window installation items from Marvin's flashing instructions

Window rows come from the manufacturer, and the checklist names the instruction it follows. Marvin's "Window Rough Opening Prep and Flashing, Method A1-Membrane Drainage System" covers new wood-frame construction. The weather resistive barrier "is to be applied prior to window installation", and head flashing goes over the face of the mounting flange (Marvin, document 19913776, dated April 29, 2026). It states plainly: "Nailing fin is not designed to be a weatherproof flashing."

Window rows from Marvin document 19913776, in installation order
StepInstructionWhat the inspector records
Barrier cutHorizontal cuts across the top and bottom of the opening, a vertical cut down the center, and 45-degree cuts away from the top corners; at the bottom corners, trim up about 2 inches, then cut about 3 1/2 inches horizontallyCut pattern; head flap tacked up
Sill panA Type III flexible membrane sill pan, with an optional sloped sill wedgePan in place before the unit
Side flapsWrapped to the interior and stapled about 1 1/2 inches from the interior edge, leaving 1 to 1 1/2 inches of bare wood, taped with seam seal tapeFlaps wrapped and taped
ShimsPlastic or composite shims at the ends and middle of the openingShim material and positions
Corner patchesA 2-inch by 4-inch strip of flashing at 45 degrees across each corner of the finFour patches per unit
Drip capFactory vinyl drip cap about 1/8 inch past each side, or a rigid head flashing; a bead of sealant under itDrip cap, extension and sealant
Jamb flashingVertical strips of adhesive flashing tape lapped onto the unit and out over the barrierJamb tape laps
Head flashingAdhesive membrane over the head jamb and sheathing, extending over the jamb flashing, top edge tapedHead over jambs, top edge taped
Head flapBarrier folded down over the head flashing; seam seal tape over the diagonal cuts, lapping onto the unit or casingFlap down and diagonals taped
Interior air sealBacker rod and sealant at the interior plane, with loose-fill fiberglass or low-expansion closed-cell foam in the cavityAir seal continuous
Exterior sealantAfter siding: a bead between finish and frame along the sides and 1 to 2 inches at the ends on top of the drip cap; sealant ASTM C920 Grade NS Class 25Product and the C920 grade on the tube

The instruction sets no fastener spacing for the fin. Spacing comes from the window unit's own installation instruction, which the checklist cites separately. Marvin also states that "Regional standard practices, environmental conditions, and codes may vary and supersede the procedures contained within." The head-flashing row therefore sits beside SPS 321.24(3)(d)1 rather than replacing it.

Header and sign-off fields

Checklist header and sign-off fields
FieldWhat goes in it
Company and jobContractor name, job number and site address
StageRoof dry-in, barrier and windows, siding, or final
Date and inspectorDate, inspector's name and the time each group of rows was checked
WeatherRain since the last inspection and temperature, for tape and sealant application limits
Roof planesEach plane with its slope and whether it covers heated space
Work by othersTrades on site whose work penetrates the envelope: plumbing vents, dryer and bath fan ducts, electrical
HoldsEach row that stopped the next trade, the correction and the release time
PhotosEach hold, and one photo per wall and roof plane before it is covered
Sign-offInspector and contractor's lead, with date and time

Filled checklist: new two-story house in Appleton, Wisconsin

The house has a 7:12 main roof, a one-story rear family room under a 4:12 roof, a 3:12 roof over an unheated front porch, and an attached garage whose 6:12 roof meets the house sidewall. It has 14 flanged windows and fiber cement lap siding. The company, house, products and findings are samples; the rules are SPS 321 and Marvin 19913776.

Filled checklist header (sample company and entries)
FieldSample entry
Company and jobExample Envelope Contractors LLC · job 26-208 · 1900 Example Lane, Appleton, WI 54913
StageRoof dry-in, barrier and windows
Date and inspectorTuesday, November 10, 2026 · J. Lindqvist, roofing at 8:10 AM, walls and windows at 10:40 AM
WeatherNo rain since November 7 · 41°F at 10:40 AM
Roof planesMain 7:12 over heated space · family room 4:12 over heated space, 18-inch overhang, 6.5-inch wall · porch 3:12 over unheated porch · garage 6:12
Work by othersPlumber: two roof vents · HVAC: 4-inch dryer duct, west wall · plumber: 7/8-inch PEX to hose bib, south wall
Filled checklist results (sample findings)
RowResultEntry
UnderlaymentOKSynthetic underlayment, data sheet citing the ASTM D 4869 water transmission test (sample product); laps per its instruction
Ice dam, appliesRecordedRequired on the family room plane only: 4:12 over heated space. Main 7:12 and garage 6:12 are over the slope limit; the porch is unheated
Ice dam, extentCorrectedFamily room: (18 + 6.5) in × 1.0541 = 25.83 in along the slope, plus 12 in = 37.83 in required, beyond the 30-in minimum. One 36-in course was down; a second course lapped over it
Ice dam, main roofOKOne 36-in course at the eaves, as the contract specifies; not required by 321.28(4) at 7:12
Fasteners per shingleOK6 nails at three lifted shingles per plane, the count in the shingle manufacturer's instruction for this job
Head lapOKWithin the manufacturer's exposure
Flashing locationsOKTwo plumbing vents booted; closed valley at the garage lined with ASTM D1970 membrane; no chimney
Barrier lapsCorrectedNorth wall, northeast corner: vertical lap 4 in; a strip added for a 6-in lap and taped
Small penetrationsOK7/8-in PEX, 0.60 sq in: sealed
Large penetrationsHoldDryer duct, 4-in round, 12.57 sq in: over 5 sq in, so flashed under 321.24(3); flashing block not yet on site. Siding held on the west wall
Window W-6, head flapCorrectedHead flap taped down before the head membrane went on; tape cut, flap lifted, membrane installed over the jamb tape, flap folded down and diagonals taped
Windows, all othersOK13 units: pan, corner patches, jamb then head laps, flap down
Eave against sidewallHoldGarage roof meets the house's east wall with no diverter; kick-out to be installed before siding on that wall
During-construction ruleHoldPatio door in the south wall not delivered; under 321.24(2), cavity insulation in that wall waits for the door, and siding waits for its flashing
Sign-offPartial releaseSiding released on the north wall, 11:55 AM; south, west and east walls held

Two holds share a pattern: a small item, and a siding crew ready to cover it. The dryer duct is 12.57 square inches, so a bead of caulk does not satisfy 321.24(4)(e). The kick-out is the diverter 321.24(3)(f) requires at the garage eave. Both are fixed with the barrier exposed, before siding covers the wall.

Checklist procedure from dry-in to final caulk

  1. Record each roof plane's slope and whether it covers heated space, then decide the ice dam rows before the first course of membrane goes down.
  2. Compute the ice dam width for every plane the rule reaches, as overhang plus wall thickness along the slope plus 12 inches, and compare it with 30 inches.
  3. Check underlayment, valleys, roof openings and nail counts plane by plane before shingles cover each one.
  4. Walk every wall for barrier coverage and laps, then measure every penetration and mark it sealed or flashed.
  5. Check each window against the manufacturer's steps in order, before the next step covers the last.
  6. Check flashing at heads, trim, ledgers, roof-wall intersections and each eave that meets a sidewall.
  7. Release walls one by one, and hold any wall with an open row, recording the reason and the correction needed.
  8. At final, confirm each held row has a release time and a photo, and that exterior sealant at the windows carries the ASTM C920 grade.

Work order software and the envelope checklist

On paper, the checklist is signed on the tailgate and the photos that prove its rows sit in someone's phone.

In FieldRanger, custom checklists carry job-specific rows for quality and compliance, and before and after photos attach to the work order. The work order puts job details, customer information and instructions on the assigned technician's phone, and the customer signs on site as proof of completion. Job status is visible to dispatchers in real time, and job completions and notes are logged to the HubSpot timeline. Photos taken on the job sync to the customer's HubSpot record. The work order software page describes the work order those rows ride on.

Each day is its own job in FieldRanger, so an envelope inspection on Tuesday and the siding release on Friday are two jobs; multi-day jobs are not built. The dispatcher reads each failed row and schedules the siding job for that wall only after the row is released. The roofing estimate template prices the ice dam courses and flashing these rows inspect, and the roofing invoice template bills them.

Fill it in here, or download the spreadsheet

The form below is the same template: totals calculate as you type, with the spreadsheet's own formulas, and your entries stay in this browser. Download it filled in, print it or save it as a PDF, or take the blank file.

Frequently asked questions

What is on a construction roofing, siding and windows checklist?

Roof underlayment, ice dam protection, shingle fasteners and head lap, valley and roof-opening flashing, the water-resistive barrier and its laps, wall penetrations, window flashing in the manufacturer's order, head and trim flashing, and the diverter where a roof eave meets a sidewall, each checked before the next layer covers it.

Is ice and water shield required on roofs in Wisconsin?

Under SPS 321.28(4), ice dam protection is required on shingled or shake roofs over a heated area of a dwelling or attached garage with a slope of 4:12 or less. It extends at least 30 inches up the slope from the edge and at least 12 inches beyond the inner face of the exterior wall.

How is a window flashed with house wrap?

In Marvin's method A1, the wrap is cut and folded before the window goes in, a flexible sill pan is installed, the jambs are taped over the fin, a head membrane laps over the jamb tape, and the wrap's head flap is folded down over the head membrane with its diagonal cuts taped.

How many nails per shingle does the Wisconsin code require?

SPS 321.28(3)(a)4 requires at least 4 fasteners per strip shingle or 2 per interlocking shingle, unless the manufacturer has other specifications.

Is there a free printable roofing, siding and windows checklist PDF?

The checklist is a free .xlsx download with no sign-up: a Template sheet with one row per check and a result column, and a Sample sheet with the filled inspection. Excel or Google Sheets saves it as a printable PDF.

The garage kick-out and the dryer duct on job 26-208

The Appleton house left Tuesday's inspection with one wall released and three held. The east wall waits for a kick-out at the garage eave, the west wall for a flashing block around a 12.57-square-inch duct, and the south wall, insulation and siding both, for a patio door under SPS 321.24(2). Each hold has one item to fix and one photo to take before release. The roofing estimate and invoice for job 26-208 come from the free field service templates. A crew that wants the hold photos on the same record as the checklist rows can compare plans on pricing and open Start free trial for 14 days, card not required.