Guide
HVAC Quote:Equipment, Load Sizing, Labor, Permits, SEER2 Minimums and Online Quote Requests
HVAC quote guide: pricing equipment, load sizing, labor, permits and HERS checks against DOE SEER2 minimums, with a costed San Diego heat pump replacement.
An HVAC quote is a fixed price for defined heating or cooling work: equipment by model, labor, materials, permit and inspection fees, and the payment terms, valid until a stated date. A replacement quote starts from a load calculation and equipment rated at or above the federal SEER2 minimum for the installation address.
A quote that leaves out a line becomes a margin problem on installation day: the permit fee the contractor absorbs, the second technician the price assumed away, or a condenser that cannot legally be installed in the customer's state. The HVAC software from FieldRanger runs inside HubSpot, and this guide sits among its pricing and quoting guides. Its order follows the lines of the document: the two kinds of quote, the equipment line and its efficiency floor, load sizing, labor, permits and inspections, and the refrigerant and tax-credit wording for 2026. A costed heat pump replacement in San Diego, online quote requests and a checklist follow.
Three ratings appear on every replacement quote. SEER2 measures seasonal cooling efficiency, EER2 cooling efficiency at a single peak test condition, and HSPF2 a heat pump's seasonal heating efficiency; the federal standards for products made from January 1, 2023 are written in these ratings (10 CFR 430.32, via Cornell LII, checked November 12, 2026). A load calculation estimates the heating and cooling a house needs, in Btu per hour. A certified combination is an outdoor unit and an indoor coil or air handler rated together, so the rating belongs to the pair rather than to either unit.
Repair quotes and replacement quotes
A repair quote prices a diagnosed fault at one figure: the failed part, the labor to replace it and the trip, approved before work starts. A replacement quote prices a system: the load, the equipment pair, its rating, the refrigerant, the permit and the options. The HVAC estimate template lays out every field of the second document, with a filled Albuquerque example, and names it an estimate; this guide covers how the numbers in those fields are built. Each kind also has its own page: the HVAC repair quote for diagnosed faults and the HVAC replacement quote for systems.
Both kinds share one formula. The full cost of the job, divided by one minus the target margin, gives the price; what differs is the number of lines that feed the cost.
Equipment lines and DOE SEER2 minimums
The equipment line names each unit by make, model and capacity, and the efficiency line states the certified combination's ratings next to the federal floor. Under 10 CFR 430.32(c)(5), split-system air conditioners manufactured from January 1, 2023 must reach 13.4 SEER2 nationally, and split-system heat pumps 14.3 SEER2 and 7.5 HSPF2. Paragraph (c)(6) raises the floor for split air conditioners installed from the same date in two regions: 14.3 SEER2 below 45,000 Btu per hour and 13.8 SEER2 at or above it, in both the Southeast and the Southwest. The Southwest, which is Arizona, California, Nevada and New Mexico, adds an EER2 floor of 11.7 below 45,000 Btu per hour, or 9.8 for a system rated 15.2 SEER2 or more.
The national standard follows the manufacture date, and the regional standards follow the installation date. That difference decides what a quote may offer. A 3-ton, 13.4 SEER2 split air conditioner made in 2024 meets the national floor and can be quoted in Ohio, but it cannot be installed in Texas or Arizona, where the regional floor below 45,000 Btu per hour is 14.3 SEER2. A split heat pump faces only the national heat pump standard, in every region.
Load calculation and system size
The capacity on the quote comes from a load calculation, not from the label on the unit being replaced. Section M1401.3 of the International Residential Code requires heating and cooling equipment to be sized under ACCA Manual S, based on building loads calculated under ACCA Manual J or another approved method. Idaho's Division of Occupational and Professional Licensing quotes the section in its implementation guide and applies its Manual S, J and D review to new residential HVAC permits only (Idaho DOPL, Manual S, J & D implementation, checked November 12, 2026). Whether a replacement permit needs the report is therefore a local question, and the building department answers it before the quote is written.
Copying the old unit's tonnage carries its sizing forward, including any error made when the house was built or since it was insulated. A Manual J taken on the site visit fixes the capacity that every other line of the quote depends on.
Labor hours, crew and loaded rate
Labor is priced as crew-hours at a loaded rate. The Bureau of Labor Statistics reports a median wage of $29.33 an hour for heating, air conditioning and refrigeration mechanics and installers in May 2025 (BLS Occupational Outlook Handbook, page modified October 29, 2026). Wages are 70.0% of total compensation in private industry (BLS Employer Costs for Employee Compensation, June 2026), so the loaded cost is $29.33 ÷ 0.700, or $41.90 an hour.
Crew-hours come from the company's own completed installs of the same type: a like-for-like condenser swap, a split system with a new line set, or a furnace replaced by a heat pump air handler. Each adds work the one before it does not, and a price copied from one type to another loses the difference.
Permit, HERS and inspection lines
The permit is a line on the quote rather than an overhead absorbed later, because its fee and its inspection belong to the job. In California, the Energy Commission states that a permit is required when an HVAC unit is replaced or altered, that the contractor seals and tests the ducts, and that a third-party HERS rater verifies the installation, including duct leakage (California Energy Commission, building energy efficiency resources for single-family homes, checked November 12, 2026).
Fees come from the jurisdiction's own schedule. For a single-family home, San Diego's mechanical fee bulletin lists $131.52 for a condensing unit and $176.57 for a first air handler, mini-split or furnace, with $52.39 for each additional unit. It requires a HERS rating for a condensing unit replacement where more than 40 feet of duct runs in unconditioned space (City of San Diego, Information Bulletin 103, May 2026). The quote states who pulls the permit and who books the inspector and the rater, because each visit needs access to the house.
Refrigerant and tax-credit lines in 2026
Two lines that quotes carried in earlier years need new wording. The refrigerant line names the refrigerant and, for R-410A equipment, the date its components were made. A final rule signed by the EPA Administrator, posted in prepublication form in May 2026, removes the installation deadline for residential and light commercial air conditioning and heat pump systems whose specified components were all made in or imported into the United States before January 1, 2025 (EPA, Technology Transitions reconsideration final rule, prepublication version). Naming the refrigerant also tells the next service technician what is in the system.
The federal tax-credit line comes off. The IRS states that the Energy Efficient Home Improvement Credit is allowed for qualifying property placed in service on or after January 1, 2023, and before December 31, 2025 (IRS, Energy Efficient Home Improvement Credit, reviewed April 28, 2026). A heat pump installed in 2026 falls outside that window, so a quote that nets the credit's former $2,000 annual heat pump limit out of the price states a figure the customer cannot claim.
Sample heat pump replacement quote in San Diego
The sample replaces a 3-ton split air conditioner and its furnace with a 3-ton split heat pump and matched air handler at a single-family house in San Diego. Equipment and material prices, crew-hours, the rater's fee and the margin are sample figures; the labor rate, the mileage rate and the permit fees are the sourced ones above. The pair is rated 15.2 SEER2 and 7.8 HSPF2 in the sample, which clears the national heat pump floor of 14.3 and 7.5. Mileage uses the IRS business rate of 76 cents a mile from July 1, 2026 (IRS standard mileage rates, updated July 28, 2026).
| Line | Basis | Amount |
|---|---|---|
| Heat pump, 3 ton, 15.2 SEER2 and 7.8 HSPF2 | Sample distributor price | $3,650.00 |
| Matched air handler | Sample distributor price | $1,980.00 |
| Line set, pad, disconnect and whip, condensate, thermostat | Sample materials | $540.00 |
| Installation labor | 20 crew-hours × $41.90 | $838.00 |
| Vehicle | 2 round trips of 24 miles × $0.76 | $36.48 |
| Permit | $131.52 condensing unit + $176.57 air handler | $308.09 |
| HERS verification | Sample rater fee | $350.00 |
| Removal and disposal of the old equipment | Sample cost | $60.00 |
| Full cost | Sum of the lines | $7,762.57 |
| Quoted price at a 35% margin | $7,762.57 ÷ 0.65 | $11,942.42 |
Equipment is 72.5% of the full cost and labor 10.8%, so an error in the distributor price moves the quote further than a missing technician-hour. The permit and the rater together cost $658.09; the margin on the job is $4,179.85, and a quote that left both lines out would lose 15.7% of it.
An option line for a split air conditioner in place of the heat pump would need 14.3 SEER2 and 11.7 EER2 at this address below 15.2 SEER2, because California sits in the Southwest region. The option is priced outside the total, with its own certified combination and rating.
HVAC quote online: instant prices and their limits
An HVAC quote online takes two forms: a request form that books the site visit, and an instant price generated from the customer's answers about floor area and the existing system. The instant figure cannot know three facts that set the price: the Manual J load, whether the existing ducts pass a leakage test where one is required, and whether the electrical panel has capacity for the new unit. An online price is therefore a range, and the quote the customer signs is written after the visit. It states the assumptions the online figure made: the tonnage, the equipment tier, and whether the permit and rater are included.
The online request is also the first entry in the deal's record: the customer's answers, any photos uploaded and the visit booked. A quote written from that record starts with the customer's own description of the problem.
HVAC quote checklist
- Confirm the jurisdiction, its permit type and fee, and whether a HERS rater or a Manual J report is required.
- Run the load calculation and select the capacity from it.
- Select a certified combination and check its ratings against the floor for the installation address.
- Name each unit by make, model, capacity and refrigerant.
- Price materials as separate lines: line set, pad, disconnect and whip, condensate and thermostat.
- Price labor as crew-hours from completed jobs of the same type, at the loaded rate.
- Add the permit, inspection and rater fees, the vehicle and disposal.
- Remove any federal tax-credit figure for equipment placed in service in 2026.
- Divide the full cost by one minus the target margin, and price options outside the total.
- State the expiry date, the deposit, the payment terms and who books each inspection.
- Verify after installation: compare actual crew-hours and materials with the quote, and record the final inspection date on the job.
HVAC quotes on the HubSpot deal with FieldRanger
FieldRanger keeps the quote where the sale is tracked. An estimate is built from the HubSpot deal or contact record without leaving HubSpot, or built in FieldRanger and kept tied to the deal it belongs to, and PandaDoc sends it for signature. A won HubSpot deal becomes a job with its context carried over. Technicians clock in and out with time logged against each job, which supplies the actual hours that step 11 compares, and revenue reports show job revenue and margin by service type, so replacements and repairs can be read separately. After the install, recurring job templates schedule the maintenance visits that the HVAC maintenance checklist covers. The estimating software page sets out the estimate workflow. Pricing lists the plans, and Start free trial lasts 14 days and needs no card.
Frequently asked questions
What is included in an HVAC quote?
The equipment by make, model and capacity, the certified efficiency ratings, materials, labor, permit and inspection fees, disposal, options priced outside the total, the expiry date and the payment terms.
How to price an HVAC replacement quote?
Add equipment, materials, crew-hours at a loaded rate, the vehicle, permit, rater and disposal, then divide by one minus the target margin. The San Diego sample in this guide costs $7,762.57 and is quoted at $11,942.42 at a 35% margin.
What SEER2 rating is required for a new system?
Nationally, 13.4 SEER2 for split air conditioners and 14.3 SEER2 with 7.5 HSPF2 for split heat pumps. Split air conditioners below 45,000 Btu per hour installed in the Southeast or the Southwest need 14.3 SEER2, and the Southwest adds an EER2 floor.
Can an HVAC quote be given online?
An online form can give a range. The load, the condition of the ducts and the capacity of the electrical panel are known only after a site visit, so the signed quote follows the visit and states the assumptions the online figure made.
Does an HVAC quote in 2026 include the federal tax credit?
No. The IRS states that the Energy Efficient Home Improvement Credit covers qualifying property placed in service before December 31, 2025, so a heat pump installed in 2026 falls outside it.
How long is an HVAC quote valid?
Until a date printed on the quote, set by how long the distributor's equipment prices hold. A date, rather than a number of days, leaves no argument about when the price lapsed.
On the San Diego sample, a $308.09 permit and a $350.00 rater are the two lines easiest to leave off, and together they would take 15.7% of the job's gross profit.
Run field service on HubSpot with FieldRanger
Estimates with e-signature, scheduling and dispatch, a technician mobile app and invoicing, synced to the HubSpot deals and contacts the business already keeps.
Book a demo