Template

Free HVAC Estimate Template:Every Field and a Filled Air Conditioner Replacement Example

HVAC estimate template with equipment, labor, permit, refrigerant and SEER2 efficiency fields, filled for an air conditioner replacement in Albuquerque.

Updated 9 min read

Download .xlsxExcel spreadsheet · 13 KB · Free, no sign-upFill it in online

An HVAC estimate template is the priced offer for new heating or cooling equipment: the load and the system selected, each piece of equipment by model, labor, the permit, the refrigerant, the efficiency rating against the federal minimum, the price and the terms. The example fills every field for an air conditioner replacement in Albuquerque, New Mexico.

The field list is one of the free field service templates from FieldRanger, the HVAC software that runs inside HubSpot. How an HVAC office prices and sells replacements, from tiered proposals to the deal record, is the subject of the HVAC estimating page.

Fields of an HVAC estimate: equipment, labor, permit, refrigerant and efficiency

The table holds the template's fields, and the page offers them as a free .xlsx download with no sign-up. Each row becomes a line in a Word or Google Docs copy, or a row in a spreadsheet that totals itself.

HVAC estimate template fields and what goes in each
FieldWhat goes in it
ContractorBusiness name, address, telephone and contractor license number
Estimate number, date and expiryA unique number, the issue date and the date equipment prices lapse
Customer and siteName, address and where each unit sits: yard, roof, attic, closet or garage
Existing equipmentMake, model, age, refrigerant and condition of each unit replaced or kept
Load calculationMethod, cooling and heating loads in Btu/h, and the capacity selected
Outdoor unitMake, model, capacity and refrigerant
Indoor coil or air handlerMake and model, matched to the outdoor unit
Efficiency ratingSEER2, EER2 and HSPF2 of the certified combination, its reference number, and the federal minimum for the region
RefrigerantNew refrigerant and charge, added charge for line length, and recovery of the old charge
Installation materialsLine set, pad, disconnect, drain pan and float switch, thermostat: one line each
LaborCrew size, hours and rate, or a set price per task; removal and haul-away
Startup and commissioningThe tests run before the crew leaves: charge, airflow, temperature split
PermitJurisdiction, permit type, fee billed at cost, and who schedules the inspection
OptionsAlternative systems, priced outside the total
Subtotal and taxThe sum of the lines, and how the state's tax is added
WarrantyManufacturer's parts warranty and its registration condition; labor warranty
Payment termsDeposit, balance due date and payment methods
AcceptanceCustomer's signature, date and the option chosen

Filled HVAC estimate: 3-ton air conditioner replacement in Albuquerque, New Mexico

A 2009 air conditioner failed with a dead compressor on a no-cool call. The gas furnace, installed in 2017, stays; the condenser, coil and line set are replaced. The business, customers, model numbers and prices are illustrative.

Filled HVAC estimate, header and terms (example business, illustrative entries)
FieldExample entry
ContractorExample Heating and Air LLC, 400 Example Boulevard NE, Albuquerque, NM 87110 · 505-555-0126 · license 000000 (example)
Estimate number, date and expiryHV-2026-0274 · November 12, 2026 · valid until December 12, 2026
Customer and siteDaniel and Rosa Chavez, 815 Example Drive NE, Albuquerque, NM 87112 · condenser on a ground pad in the side yard; furnace and coil in the garage
Existing equipmentSplit air conditioner, 3 ton, installed 2009, R-22, compressor failed (work order WO-2026-1932) · gas furnace, installed 2017, kept
Load calculationACCA Manual J: cooling load 33,400 Btu/h; 3 ton (36,000 Btu/h nominal) selected
Outdoor unitSplit air conditioner EX-AC36 (example), 3 ton, R-454B
Indoor coil or air handlerCased evaporator coil EX-C36 (example) with TXV, matched to EX-AC36
Efficiency ratingCertified combination 15.0 SEER2 and 12.0 EER2, reference 000000000 (example) · Southwest minimum below 45,000 Btu/h: 14.3 SEER2 and 11.7 EER2
RefrigerantR-454B, factory charged for 15 ft of line, plus 0.9 lb for the 30 ft run · existing R-22 recovered by a Type II certified technician
PermitCity of Albuquerque plumbing/mechanical permit for a cooling system installation, fee at cost; inspection scheduled by the contractor as permit owner
Subtotal and taxNew Mexico gross receipts tax added as a separate line at the job site's rate on the invoice date
WarrantyManufacturer's parts warranty on registration within the manufacturer's deadline · labor one year
Payment terms$2,500 at acceptance to order equipment; balance on completion · card, check or bank transfer
AcceptanceCustomers' signatures, date and the option chosen
Filled HVAC estimate, equipment, labor and permit lines (illustrative prices)
LineQuantityUnit priceLine total
Outdoor unit EX-AC36, 3 ton, R-454B1$3,950.00$3,950.00
Cased evaporator coil EX-C36 with TXV1$1,280.00$1,280.00
Line set, 3/8 x 3/4 inch, insulated30 ft$9.50$285.00
Equipment pad, 60 A non-fused disconnect and whip1 lot$210.00$210.00
Secondary drain pan and float switch1$145.00$145.00
Programmable thermostat1$185.00$185.00
Recover R-22 charge; remove and haul away condenser and coil1 lot$350.00$350.00
Installation labor, two technicians16 h$135.00$2,160.00
Additional R-454B for line length0.9 lb$48.00$43.20
Startup and commissioning: subcooling, temperature split, static pressure1$225.00$225.00
Mechanical permit, at cost1$160.00$160.00
Subtotal before gross receipts tax$8,993.20
Option, outside the subtotal: 3-ton heat pump and matched coil in place of EX-AC36, 16.0 SEER2 and 8.1 HSPF21add $2,450.00

The coil is replaced for two reasons: the 2009 coil was built for R-22, and the new outdoor unit is rated only as a certified combination with a matched coil. Keeping the old coil would leave the efficiency row with no rating to enter.

Efficiency, refrigerant and permit rows in the example

Four rows of the Albuquerque estimate rest on rules outside the contractor's choice.

Federal minimum efficiency for split-system central air conditioners installed from January 1, 2023 (U.S. Department of Energy)
Cooling capacityNorthSoutheastSouthwest
Below 45,000 Btu/h13.4 SEER214.3 SEER214.3 SEER2; 11.7 EER2, or 9.8 EER2 at 15.2 SEER2 and above
45,000 Btu/h and above13.4 SEER213.8 SEER213.8 SEER2; 11.2 EER2, or 9.8 EER2 at 15.2 SEER2 and above

The figures come from the Department of Energy's guidance on the 2023 standards, which also sets split-system heat pumps at 14.3 SEER2 and 7.5 HSPF2 nationwide (U.S. Department of Energy, 2023 central air conditioner standards FAQ, issued October 5, 2022). The Southwest region is Arizona, California, Nevada and New Mexico. In the southern regions the standard follows the installation date, and installation means connecting the refrigerant lines or electrical systems to make the unit operational. The Albuquerque combination, at 15.0 SEER2 and 12.0 EER2, clears both southwestern minimums for its size. The heat pump option faces only the national heat pump standard, and its 16.0 SEER2 and 8.1 HSPF2 clear it.

The refrigerant row follows the EPA's Technology Transitions rule. New residential and light commercial air conditioning systems carry a global warming potential limit of 700, with an installation compliance date of January 1, 2025, and no installation deadline for systems whose specified components were all made or imported before that date (EPA, Technology Transitions restrictions by sector, updated August 28, 2026). R-454B is entered by name so the customer and the inspector read the same refrigerant. The old R-22 charge is recovered rather than vented: EPA rules prohibit intentional venting of refrigerants during service or disposal (EPA, Prohibition on Venting Refrigerants, updated December 8, 2025).

The permit row names the city's own category. Albuquerque lists "Heating or cooling system installation" among the work needing a plumbing/mechanical permit, and states that "The permit owner may schedule inspections online or by calling 505-924-3320" (City of Albuquerque, Inspections, checked November 2026). The fee line is illustrative; the city's fee schedule sets the actual amount.

The tax row adds gross receipts tax at the invoice rather than at the estimate. New Mexico imposes the tax on the business, and a business that passes it to the buyer must state it separately on the invoice; the total rate combines state, county and municipal rates for each location, and since July 1, 2025 rates change only in July, outside special cases (New Mexico Taxation and Revenue Department, Gross Receipts Tax Overview, checked November 2026).

HVAC quote template and HVAC estimate template

An HVAC quote template prices a diagnosed repair at one figure: the fault found, the part, the price and the approval, signed at the door. It has no load calculation, efficiency row or permit, because nothing new is being sized or installed. An HVAC estimate template prices a system: the load, the equipment, the combination's rating, the refrigerant, the permit and the options. The Albuquerque job produced both. The no-cool call ended with a quote for a compressor replacement that the Chavezes declined, and the estimate above replaced the system instead.

HVAC estimate and quote formats: PDF, Word and spreadsheets

An HVAC estimate template PDF and an HVAC quote template PDF are the same fields with the layout fixed, so the customer signs the page that was sent. A spreadsheet copy computes the line totals and the subtotal; a Word or Google Docs copy carries the same rows with the arithmetic done by hand. Each format works from the field table above.

HVAC estimate instructions in order of the site visit

  1. Record the existing equipment from its data plates, with photographs, and note what stays.
  2. Run the load calculation and select the capacity from it rather than from the old unit's size.
  3. Choose the outdoor unit and the matched indoor coil or air handler, and enter the certified combination's ratings and reference number.
  4. Compare the ratings with the federal minimum for the region; in the Southeast and Southwest, use the minimum in force on the installation date.
  5. Enter the refrigerant, the added charge for the line length, and the recovery of the old charge.
  6. Price materials, labor, startup and the permit as separate lines, and price options outside the subtotal.
  7. State how tax is added, the warranty and its registration condition, the deposit and the expiry date.
  8. Before sending, confirm that every rating on the page belongs to the combination quoted and that the lines add to the subtotal.

Estimating software and the signed HVAC estimate

On paper, the signed Chavez estimate is copied three times: the equipment into a distributor order, the install into the calendar, and the totals into an invoice.

In FieldRanger, an estimate is built from the HubSpot deal or contact record without leaving HubSpot, or in FieldRanger, tied to the HubSpot deal it belongs to. It goes out for signature through PandaDoc. The won deal becomes the install job with its context carried over, the dispatcher drags it onto a technician's calendar, and the deal record shows its status. Clocked time is logged against the job, and the invoice is generated from the completed work order; the HVAC invoice template lists what that bill carries. Recurring job templates then hold the maintenance visits once the customer signs an agreement drawn from the HVAC service agreement template. The estimating software page describes the estimate in detail.

FieldRanger does not calculate loads or look up certified ratings, and its price book of services, parts and rates is the contractor's own list rather than a manufacturer's. Those entries come from design software, the manufacturer and the distributor before the estimate is written.

Fill it in here, or download the spreadsheet

The form below is the same template: totals calculate as you type, with the spreadsheet's own formulas, and your entries stay in this browser. Download it filled in, print it or save it as a PDF, or take the blank file.

Frequently asked questions

What should an HVAC estimate include?

The contractor's license number, the customer and site, the existing equipment, the load calculation, the outdoor unit and matched coil by model, the certified efficiency rating against the regional minimum, the refrigerant, materials, labor, startup tests, the permit, options, tax, warranty, payment terms and acceptance.

What is the difference between an HVAC quote and an HVAC estimate?

A quote prices a diagnosed repair at one figure for approval on site. An estimate prices a system: the load, the equipment, the rated combination, the refrigerant, the permit and any options.

Is there an HVAC estimate template PDF?

The page offers a free .xlsx download with no sign-up: a Template sheet with every field and the line items, and a Sample sheet with the filled example. Excel or Google Sheets saves it as a PDF, which fixes the layout for signature.

What SEER2 rating does a new air conditioner need in the Southwest?

Under the Department of Energy standards in force since January 1, 2023, a split-system air conditioner below 45,000 Btu/h installed in Arizona, California, Nevada or New Mexico needs 14.3 SEER2 and 11.7 EER2, or 9.8 EER2 at 15.2 SEER2 and above.

Does an air conditioner replacement need a permit in Albuquerque?

The City of Albuquerque lists heating or cooling system installation among the work requiring a plumbing/mechanical permit, and the permit owner schedules the inspections.

The Chavez changeout after signature

Once the Chavezes sign HV-2026-0274, the $2,500 deposit orders EX-AC36 and its coil, the permit application names the same combination, and the inspector checks the installed model numbers against it. The startup readings recorded on the install become the baseline for the first maintenance visit, and the invoice and agreement that follow come from the same free field service templates. FieldRanger's price per technician is on pricing, and its free trial covers 14 days with no card required.

FieldRanger runs field service inside HubSpot

Estimates, scheduling and dispatch, a technician app and invoicing on the HubSpot records sales already keeps. Every plan starts with a free trial.

Book a demo