Template

Plumbing Service Agreement Template:Inspection Scope, Response Times, Visit Reports and Illinois Renewal and Cancellation Rules for a Homeowner Plan

Plumbing service agreement template with inspection scope, response times, renewal and cancellation under Illinois law, filled for a Naperville homeowner plan.

Updated 12 min read

Download .docxWord document · 52 KB · Free, no sign-up

A plumbing service agreement template is the contract for a recurring plumbing plan: the fixtures and equipment covered, what each inspection visit includes, response times for calls between visits, repair rates, the visit report, price and billing, the term, automatic renewal and cancellation. The example fills every field for a two-visit homeowner plan in Naperville, Illinois.

The field list is one of the free field service templates kept by FieldRanger, the plumbing software that runs inside HubSpot. The customer is a homeowner, so the renewal rows follow the Illinois Automatic Contract Renewal Act, which covers consumer contracts and excludes business-to-business ones. The page is not legal advice.

Plumbing service agreement fields: covered systems, visits, response, repairs and renewal

The table lists the template's fields, and the page offers the agreement as a free .docx download with no sign-up. In a Word or Google Docs version each row becomes a numbered clause, and the inspection checklist becomes an exhibit.

Plumbing service agreement template fields and what goes in each
FieldWhat goes in it
PartiesProvider and customer, with legal names, addresses and who signs
Agreement number and dateA unique number and the date of issue
CredentialsState plumbing contractor registration and the licensed plumber's license number
PropertyAddress, year built, water source, sewer or septic, and access instructions
Covered systemsWater heater, fixtures and supply lines, main shutoff, sump and ejector pumps, backflow assemblies, outdoor faucets
Inspection visitsThe month of each visit and the checklist each one completes
ReadingsWhat is measured and recorded: static pressure, water heater setting, backflow test results
Response timesPriority levels, what each covers, the hours, and the time from call to arrival
Repairs and ratesWhat the plan price excludes, the repair discount, after-hours rates and the trip fee
Visit reportWhat the report contains and when the customer receives it
Customer responsibilitiesAccess, pets, clearance around the water heater and pumps
ExclusionsSewer line replacement, fixtures beyond repair, frozen pipes in unheated spaces, damage from outside causes
Price and billingThe annual price, when it is paid and how
TermStart and end dates
Automatic renewal termsWhether the plan renews, for how long, the renewal price, and the deadline and method to cancel
Renewal noticeThe window and the delivery method for the written notice
CancellationHow the customer cancels, and refund of the unused term
InsuranceCoverage carried, and the certificate on file with the state
Governing lawThe state whose law governs
SignaturesName, signature and date for each party

Inspection scope and the Illinois Plumbing Code readings behind it

An inspection visit is a list of tasks, named one by one so that a missed task shows on the report. Two tasks in the example rest on the Illinois Plumbing Code. The first is the backflow test: Section 890.1130(b) requires that reduced pressure principle (RPZ), reduced pressure detector, double check and double check detector backflow prevention assemblies "shall be tested and approved by a Cross-Connection Control Device Inspector (CCCDI) before initial operation, and at least annually after initial inspection", and that "Records to verify testing and maintenance shall be available at the site of the installation" (77 Ill. Adm. Code 890.1130, Illinois General Assembly, amended effective April 24, 2014). A house with a lawn irrigation RPZ therefore needs a yearly test by a credentialed inspector, and the plan schedules it at irrigation start-up.

The second is the pressure reading. Section 890.1210(g) requires a pressure reducing valve, and a strainer with a by-pass relief valve, where water main pressure exceeds 80 psi, and a valve, gauge and strainer on the supply to any fixture where the pressure there exceeds 80 psi; it also allows that "Sill cocks and outside hydrants may be left on full water main pressure" (77 Ill. Adm. Code 890.1210, Illinois General Assembly, amended effective April 24, 2014). The plan reads static pressure at an indoor fixture, not at the hose bibb, and records the number.

Inspection checklist by visit in the example (sample scope; code references as cited)
TaskApril visitOctober visitBasis
Irrigation RPZ assembly test by a CCCDI, with the test record left on siteYes890.1130(b)
Outdoor faucets: leaks, vacuum breakers, frost-free stemsYesShut off and drainedSample scope
Sump pump: run test with water, float, check valve, discharge lineYesYesSample scope
Static pressure at the laundry tub, in psiYes890.1210(g), 80 psi limit
Water heater: drain sediment, operate the relief valve, record temperature setting and ageYesSample scope
Main shutoff and fixture stops: operate and check for leaksYesSample scope
Toilets, faucets and supply lines: leaks and wearYesSample scope

Filled plumbing service agreement: two-visit homeowner plan in Naperville, Illinois

The house is a 1994 two-story with a basement sump, a 50-gallon gas water heater installed in 2016 and a lawn irrigation system on an RPZ assembly. The provider, customer, credential numbers and prices are samples.

Filled plumbing service agreement (sample business and entries)
FieldSample entry
PartiesExample Plumbing Co., 220 Example Street, Naperville, IL 60540 (provider) · Hannah and Luis Carver, 1180 Sample Lane, Naperville, IL 60565 (customer)
Agreement number and datePSA-2026-0031 · November 12, 2026
CredentialsIllinois plumbing contractor registration and licensed plumber number (sample numbers); the April test by a CCCDI on staff
Covered systemsGas water heater, 50 gallons · 3 bathrooms and kitchen fixtures · main shutoff · sump pump and check valve · irrigation RPZ assembly · 3 outdoor faucets
Inspection visitsApril 2027 and October 2027, per the checklist above, each scheduled two weeks ahead
Response timesP1, active leak that cannot be shut off at a fixture stop, no water, or sewage backing up: technician on site within 4 hours, 7:00 a.m. to 9:00 p.m. daily · P2, a fixture or appliance out of service: next business day · P3, other repairs: within 5 business days
Repairs and ratesNot in the plan price; quoted before work at the provider's price book less 10% · trip fee waived · P1 calls between 9:00 p.m. and 7:00 a.m. at the after-hours rate on the price book
Visit reportEmailed the same day: checklist results, readings, photos, and recommended repairs with their priority
ExclusionsSewer line excavation or replacement · fixture and appliance replacement · frozen pipes in unheated spaces · damage from flooding or outside causes
Price and billing$264.00 for the year, paid at signing by card or check; no card is kept on file
TermJanuary 1, 2027 to December 31, 2027
Automatic renewal terms**Renews for 12 months, January 1 to December 31, 2028, at $279.00, unless the customer cancels by December 1, 2027, by email, by telephone or online through the provider's cancellation page.** Printed next to the signature line and repeated in the acknowledgment email
Renewal noticeWritten notice by email and by mail between October 2 and November 1, 2027
CancellationAt any time by the same methods; unused months of the plan refunded pro rata, less the value of completed visits at the price book rate
InsuranceCertificate on file with the Illinois Department of Public Health under the registration
Governing lawIllinois
SignaturesProvider: owner · customer: both owners · each signed and dated

Response times and the priority definitions

A response time is a promise about staffing, so the agreement names the events that start and stop the clock: the call to the provider's line and the technician's arrival. Each priority is something the homeowner can observe. "Water that cannot be shut off at a fixture stop" is a fact; "an emergency" is a judgment the two parties make differently at 8:30 p.m. The hours carry as much weight as the number: a 4-hour promise until 9:00 p.m. needs a technician on call each evening, and a 4-hour promise at any hour needs one overnight as well.

Illinois Automatic Contract Renewal Act: consumer plans, not business contracts

The Act applies to "Any person, firm, partnership, association, or corporation that sells or offers to sell any products or services to a consumer pursuant to a contract" that renews unless the consumer cancels, and Section 20(c) states that "This Act does not apply to business-to-business contracts" (815 ILCS 601/10 and 815 ILCS 601/20, Illinois General Assembly, checked November 12, 2026). The Carvers' plan is covered. The same agreement sold to a property manager for a 40-unit building falls outside the Act, and its renewal terms rest on the contract alone.

For a consumer plan, Section 10(a) requires the seller to disclose the automatic renewal offer terms "clearly and conspicuously" before the agreement is fulfilled and in visual proximity to the request for consent; not to charge the consumer's card for a renewal without consent to a contract containing those terms; and to send an acknowledgment that includes the terms, the cancellation policy and how to cancel. Section 5 defines "clear and conspicuous" as larger type than the surrounding text, contrasting type, font or color, or text set off by symbols; the example meets it with the renewal clause in bold beside the signature.

Section 10(b) adds the notice. Where the contract term is 12 months or more and it renews for more than one month, "Written notice shall be provided to the consumer no less than 30 days and no more than 60 days before the cancellation deadline". The notice states that the contract renews unless cancelled, a cancellation mechanism, and the deadline. A plan accepted online must also be cancellable online. The Carvers' deadline is December 1, 2027; 60 days before it is October 2 and 30 days before it is November 1, so the notice goes out in that window, and the October visit falls inside it. A violation is an unlawful practice under the Consumer Fraud and Deceptive Business Practices Act (815 ILCS 601/15).

Plumbing service report template: the record each visit leaves

The report is the evidence that the plan delivered its checklist. A plumbing service report template carries the visit, each task with its result, the readings and the recommendations.

Plumbing service report template fields, with the Carvers' October 2027 entries (sample)
FieldSample entry
Agreement and visitPSA-2026-0031 · October visit · October 19, 2027, 9:10 to 10:35 a.m.
TechnicianName and Illinois plumber license number (sample)
Static pressure74 psi at the laundry tub; under the 80 psi limit, no reducing valve needed
Water heaterGas, 50 gal, 2016 · set at 120°F · sediment drained · relief valve operated, reseated without dripping
Sump pumpRan on a filled pit · float free · check valve holding · discharge clear
Fixtures and stopsHall bath toilet fill valve running; all stops operate
Outdoor faucets3 shut off inside and drained
Recommended repairsReplace hall bath fill valve, P3, quoted at the plan's 10% discount
PhotosWater heater label, pressure gauge, sump pit
Customer acknowledgmentSignature on the technician's phone

The April report adds the backflow test record: the CCCDI's name and credential, the assembly's make, size and serial number, and the test result, with a copy left at the site as Section 890.1130(b) requires.

Illinois plumbing contractor registration and insurance rows

The credentials and insurance rows come from the Illinois Plumbing License Law. Contractors register with the Department of Public Health each year, and "All plumbing contractor registrations expire on the last day of September of each year." The application carries a certificate showing general liability insurance of at least $100,000 per occurrence and $300,000 aggregate for bodily injury, property damage insurance of $50,000 or a $300,000 combined single limit, and workers' compensation with $500,000 employer's liability, plus a $20,000 indemnification bond or letter of credit (225 ILCS 320/13.1, Illinois General Assembly, as amended effective July 1, 2024). A one-year agreement that starts in January spans a September renewal of the registration, so the provider's file holds both certificates.

Agreement drafting order, from walkthrough to notice window

  1. Walk the house and list every covered system with its age, size and location.
  2. Write each visit's checklist, and mark the tasks a code requires.
  3. Define each priority by an observable event, then set the hours, arrival time, repair rates, price and term.
  4. Print the renewal terms in contrasting type beside the signature, and send the acknowledgment with them.
  5. Compute the cancellation deadline and the notice window, and put both dates on the calendar.
  6. After each visit, check the report against the checklist: every task on the exhibit has a result.

Plumbing service agreement, plumbing estimate and plumbing invoice

The agreement prices the visits and the promise to arrive; it does not price the repairs the visits find. The hall bath fill valve goes on the plumbing estimate template at the plan's discount, and the completed repair is billed on the plumbing invoice template with the plan number in its header, so the discount can be traced to the agreement.

Recurring service scheduling software and the plan's two visits

In FieldRanger, the plan can be sold as a HubSpot deal and sent for signature through PandaDoc, and the won deal becomes a job with its context carried over. Recurring job templates hold the April and October visits, each with its checklist, and the dispatcher moves a visit by dragging it on the calendar. Arrival windows and on-time performance record each P1 response against the 4-hour promise. Photos of the gauge and the water heater label attach to the work order and sync to the customer's HubSpot record, and repairs are invoiced from the completed work order. The recurring service scheduling software page describes the templates.

Recurring work can be charged automatically to a card on file in FieldRanger, and a plan billed that way charges the renewal only with the consent Section 10(a) requires. The Carvers pay by card or check at signing, so their 2028 renewal fee is invoiced like the first year's. The October notice is sent by email and mail, with its date kept as a task on the HubSpot deal.

Frequently asked questions

What should a plumbing service agreement include?

The parties, credentials, property, covered systems, the inspection checklist for each visit, the readings recorded, response times by priority, repair rates, the visit report, customer duties, exclusions, price and billing, term, automatic renewal terms, renewal notice, cancellation, insurance, governing law and signatures.

Does Illinois require notice before a service plan renews automatically?

For a consumer contract with a term of 12 months or more that renews for more than one month, the Automatic Contract Renewal Act requires written notice 30 to 60 days before the cancellation deadline. The Act does not apply to business-to-business contracts.

What is the backflow preventer testing interval in Illinois?

Section 890.1130(b) of the Illinois Plumbing Code requires RPZ and double check assemblies to be tested by a Cross-Connection Control Device Inspector before initial operation and at least annually, with test records kept at the site.

What goes on a plumbing service report?

The agreement and visit, the technician and license number, each checklist task with its result, readings such as static pressure and water heater setting, recommended repairs with priority, photos, and the customer's acknowledgment.

Is there a free plumbing service agreement template?

Yes. The page offers a free .docx download with no sign-up: numbered clauses with blank lines for each field, and the filled Naperville agreement in an appendix titled Sample.

Plan PSA-2026-0031 from the April backflow test to the December 1 deadline

The Carvers' year has three fixed dates: the April RPZ test, with its record left beside the assembly; the October visit, with the 74 psi reading and the fill valve quote; and the notice, mailed and emailed between October 2 and November 1, 2027, naming December 1 as the last day to cancel. The estimate and invoice forms for the repairs in between are among the free field service templates. Per-technician plans are on pricing, and Start free trial runs 14 days with no card required.

FieldRanger runs field service inside HubSpot

Estimates, scheduling and dispatch, a technician app and invoicing on the HubSpot records sales already keeps. Every plan starts with a free trial.

Book a demo