An electrical service agreement template is the contract for recurring maintenance of a client's electrical distribution equipment: the equipment schedule, infrared thermography and panel inspections at stated intervals, response times for breakdowns, repair rates, reports, price and billing, the term, automatic renewal and cancellation. The example fills every field for a packaging plant in Milwaukee, Wisconsin.

The field list is one of the free field service templates kept by FieldRanger, the electrical contractor software that runs inside HubSpot. The client is a business, so the renewal clause falls under Wisconsin's statute for business contracts, not a consumer law. The page is not legal advice.

Electrical service agreement fields: equipment, inspections, response and renewal

The table lists the agreement's fields; the page offers them as a free .docx download with no sign-up. In Word or Google Docs, each row becomes a numbered clause, and the equipment schedule becomes an exhibit.

Electrical service agreement template fields and what goes in each
FieldWhat goes in it
PartiesLegal names and addresses of provider and customer, and who signs for each
Agreement number and dateA unique number and the date of issue
CredentialsThe provider's electrical contractor and master electrician credential numbers where the state issues them
Site and contactsAddress, buildings, site contact, escort and access rules
Equipment scheduleEach item by tag: switchboards, panelboards, motor control centers, transformers, transfer switches, with rating and location
Condition ratingThe condition assigned to each item at the baseline survey, and the interval it sets
Infrared thermographyWhich items, how often, at what load, and the report delivered
Panel inspectionsVisual checks, cleaning, connection checks and breaker exercise, energized or during a shutdown
Shutdown windowsThe dates the customer provides for de-energized work
VisitsThe month of each scan and inspection, and what each visit covers
Response timesPriority levels, what each covers, and the time from call to arrival
Repairs and ratesRepairs excluded from the price, the labor rates, overtime and parts pricing
ReportsWhat each visit report contains and when it is delivered
Customer responsibilitiesAccess, escorts, load during scans, a current single-line diagram
SafetyThe provider's electrical safety program and its rules for energized work
ExclusionsGenerators, UPS units, utility-owned equipment, code upgrades, damage from outside causes
Price and billingThe annual price and the invoice schedule
TermInitial term, with start and end dates
Automatic renewal disclosureWhether the agreement renews, for how long, any price increase, how to decline and by when
Renewal noticeThe window and the delivery methods for the reminder
CancellationGrounds, notice and refund of prepaid amounts
Insurance and liabilityCoverage carried and certificates delivered
Governing lawThe state whose law governs the agreement
SignaturesName, title, signature and date for each party

Thermography and inspection intervals under NFPA 70B

The inspection rows cite a standard rather than a habit. NFPA 70B covers the maintenance of electrical equipment, and Teledyne FLIR summarizes its 2023 edition: "In 2023, NFPA70B makes mandatory the inspection of ALL electrical equipment at least every 12 months", with "equipment that meets the Equipment Physical Condition 3 requiring thermographic inspection at least every 6 months" (Teledyne FLIR, NFPA 70B 2023: New Guidelines for Electric Inspections, April 4, 2023).

The agreement turns that into two rows. A baseline survey assigns each item a condition rating; every item is scanned once a year, and any Condition 3 item again six months later. The agreement names the edition it follows.

Filled electrical service agreement: packaging plant in Milwaukee, Wisconsin

The plant runs two production lines from one service; its line 2 motor control center sits beside a dusty corrugator. The business, plant, credential numbers and prices are illustrative.

Equipment schedule for the example agreement (illustrative entries)
TagEquipmentRatingLocationCondition at baselineThermography
MSB-1Main switchboard3,000 A, 480Y/277 VElectrical room A2February
DP-1 to DP-4Distribution panelboards800 A, 480 VProduction floor2February
MCC-1Motor control center1,200 A, 480 VLine 12February
MCC-2Motor control center1,200 A, 480 VLine 2, beside the corrugator3February and August
T-1 to T-6Dry-type transformers75 kVA, 480 to 208Y/120 VMezzanine2February
LP-1 to LP-18Branch panelboards225 A, 208Y/120 VThroughout2February
ATS-1Automatic transfer switch800 AElectrical room A2February
Filled electrical service agreement, terms (example business, illustrative entries)
FieldExample entry
PartiesExample Electrical Services LLC, 2200 Example Street, Milwaukee, WI 53204 (provider) · Example Packaging Inc., 4400 W. Sample Avenue, Milwaukee, WI 53209 (customer)
Agreement number and dateESA-2026-0057 · November 12, 2026
CredentialsWisconsin electrical contractor credential 0000000 and master electrician credential 0000000 (examples)
Site and contactsOne building of 120,000 sq ft · maintenance manager as site contact · escort required on the production floor
VisitsFebruary: thermography of every item under production load · July shutdown week: de-energized inspection of MSB-1, DP-1 to DP-4 and both motor control centers, with cleaning, connection checks to manufacturer torque values and breaker exercise · August: thermography of MCC-2 · each quarter: visual inspection of 6 branch panelboards
Response timesP1, loss of power to a production line, smoke, arcing or burning odor: on site within 4 hours, 24 hours a day · P2, a failed circuit that does not stop production: next business day by 10:00 AM · P3, other repairs: scheduled within 10 business days
Repairs and ratesNot in the price; quoted before work · $128.00 an hour straight time, $192.00 an hour overtime and nights · parts at the provider's list price less 10%
ReportsThermography report within 10 business days, with an image pair, temperature rise, priority and recommended action for each finding · inspection checklist for each item
Customer responsibilitiesAccess and escort · both lines at normal production load during scans · the July shutdown window · a current single-line diagram
SafetyWork under the provider's written electrical safety program; energized work only as that program allows
ExclusionsStandby generator and UPS maintenance · utility-owned equipment · code upgrades · damage from lightning, flooding or misuse
Price and billing$16,800.00 a year, invoiced quarterly in advance: $4,200.00 on January 1, April 1, July 1 and October 1
TermJanuary 1, 2027 to December 31, 2029
Automatic renewal disclosureRenews for one 2-year term on January 1, 2030 unless the customer declines by October 2, 2029 · price rises 3.5% at renewal, to $17,388.00 a year · decline by letter or by email to the provider's contracts address · printed in bold on page 3 and initialed there by the customer
Renewal noticeSent between August 3 and September 17, 2029, by regular U.S. mail to the customer's business address and by email
CancellationEither party, for a material breach not cured within 30 days of written notice; prepaid quarters refunded pro rata
Insurance and liabilityGeneral liability and workers' compensation certificates delivered at signing
Governing lawWisconsin
SignaturesProvider: owner. Customer: plant manager. Each signed and dated

Response times and the priority definitions

A response time is a promise about staff, so the agreement defines what starts the clock and what counts as arrival: here, from the call to the service line until a technician is on site. Four hours at any hour for a P1 call means a technician on call every night of the term.

The priority definitions carry the weight. "Loss of power to a production line" is a fact the plant manager can observe; "urgent" is not. An agreement that adds service credits for missed arrivals, or a resolution clock, has become a service level agreement template.

Wisconsin's renewal disclosure and notice rules for business contracts

The renewal rows follow Wis. Stat. 134.49, which governs business contracts: contracts for business services that directly benefit the end user, bought by a customer that conducts business in Wisconsin. The statute excludes listed categories, among them elevator and escalator service. Where a contract renews automatically for more than one month, the seller must either "present to the customer a copy of a form" with the disclosures and "obtain the customer's signature on the form", or "Include the disclosures required under par. (b) in the contract in a conspicuous manner" and "obtain the customer's initials on the contract on a page on which a disclosure appears". The disclosures cover the renewal, its length, any price increase, how to decline and the deadline. Without them, the renewal provision is unenforceable and the contract ends with its current term.

A second duty applies when the contract "has an initial term of more than one year" and renews for "an additional term of more than one year". The seller then sends notice "at least 15 days but not more than 60 days before the deadline for the customer to decline renewal or extension". The notice states that the contract renews unless declined, the deadline, any increase in charges, and the action the customer must take. Delivery may be by regular U.S. mail, registered or certified mail, personal delivery to an owner, officer, director or managing agent, or on the first page of a monthly invoice in bold type of at least 12 points. Fax, email and overnight courier count only where the contract lets the customer decline by the same method (Wis. Stat. 134.49, 2023-24 statutes updated through 2025 Wis. Act 247, published November 4, 2026).

The example's dates follow from the October 2, 2029 deadline. Sixty days before it is August 3, and fifteen days before it is September 17. The agreement lets the customer decline by email, so email is a valid route for the notice; the plant is invoiced quarterly, so the monthly-invoice route is closed to it.

Electrical service agreement drafting, from baseline survey to renewal window

  1. Walk the site with the single-line diagram and tag every item for the equipment schedule.
  2. Rate each item's condition at the baseline survey and set its thermography interval from the edition of NFPA 70B the agreement cites.
  3. Agree the visit months, the shutdown window and the production load needed during scans.
  4. Define the priorities, response times, repair rates and report contents.
  5. Set the price, billing and term; print the renewal disclosure conspicuously and take the customer's initials on that page.
  6. Compute the decline deadline and the notice window, and list the methods the customer may use to decline.
  7. After signing, put both ends of the notice window on the calendar, and check the equipment schedule against the first thermography report for items missed.

Electrical service agreements, estimates and quotes

The agreement prices attention: scheduled scans, inspections and a promised arrival. It excludes the repairs those visits find. Repair work of uncertain scope is priced on the electrical estimate template at the agreement's rates; a fixed-price replacement of a hot bus connection on DP-3 goes on the electrical quote template. The HVAC service agreement template covers a residential plan under a consumer statute, and the general service agreement template serves any recurring trade.

Recurring service scheduling software and the inspection calendar

On paper, the agreement sits in a cabinet, the scan reports in an inbox, and the 2029 notice window in someone's memory.

In FieldRanger, the agreement can be sold as a HubSpot deal and sent for signature through PandaDoc, and the won deal becomes a job with its context carried over. Recurring job templates hold the February scan, the July shutdown, the August scan and the quarterly panel visits. Skill-based assignment matches each scan to a technician by certification. Arrival windows and on-time performance record each P1 response, and a checklist per item records the inspection. Job files and images can be kept in Google Drive; repairs are invoiced from the completed work order. The recurring service scheduling software page describes the templates.

Job status changes can trigger HubSpot workflows: the completed August 2029 scan falls inside the notice window and can create the task to send the notice. Sales Hub Starter includes "Up to 50 workflows with restricted triggers and actions", and Professional "Up to 300 fully customizable workflows" (HubSpot, Sales Hub pricing, checked November 2026). The notice itself is sent by mail and email, and the quarterly invoices can be charged automatically to the client's card on file through autopay.

Frequently asked questions

What should an electrical service agreement include?

The parties, credentials, site, an equipment schedule with condition ratings, thermography and panel inspection intervals, shutdown windows, response times, repair rates, reports, customer duties, safety, exclusions, price and billing, term, renewal disclosure and notice, cancellation, insurance, governing law and signatures.

At what interval should electrical equipment have infrared thermography?

Teledyne FLIR summarizes the 2023 edition of NFPA 70B as requiring inspection of all electrical equipment at least every 12 months, and thermographic inspection at least every 6 months for equipment in Equipment Physical Condition 3. The example scans every item each February and its Condition 3 motor control center again in August.

What response time should a commercial electrical service agreement promise?

The time is a term of the agreement, stated by priority. The Milwaukee example promises a technician on site within 4 hours at any hour for loss of power to a production line, the next business day for a failed circuit, and 10 business days for other repairs.

Does Wisconsin regulate automatic renewal of business service contracts?

Yes. Wis. Stat. 134.49 requires a signed disclosure form, or a conspicuous disclosure initialed by the customer, when a business contract renews automatically for more than one month. Without it, the renewal provision is unenforceable.

When must a Wisconsin automatic renewal notice be sent?

For a contract with an initial term over one year that renews for more than one year, at least 15 and not more than 60 days before the customer's deadline to decline, by a method the statute allows.

Is there a free electrical service agreement template?

Yes. The page offers a free .docx download with no sign-up: each field as a numbered clause with blank lines to fill, and the filled Wisconsin agreement in a Sample appendix.

The plant's August 3 to September 17, 2029 window

Agreement ESA-2026-0057 runs three years before its renewal question arrives, and the question has a date range: a notice by mail and email between August 3 and September 17, 2029, stating the October 2 deadline and the $17,388.00 renewal price. Before then come three February scans, three July shutdowns and three August scans of MCC-2. The repairs those visits find go on the estimate and quote forms in the free field service templates. Plans for the crews that run such a calendar are on pricing, priced per technician, and Start free trial gives 14 days with no card.

FieldRanger runs field service inside HubSpot

Estimates, scheduling and dispatch, a technician app and invoicing on the HubSpot records sales already keeps. Every plan starts with a free trial.

Book a demo